Free
Schonstedt MAC 51Bx Magnetic Locator-Rental
The MAC-51Bx consists of a receiver and a transmitter that simultaneously transmits on two frequencies - 571 Hz (LF) and 82.5 KHz (HF). The receiver has a three position switch that lets you change modes, "on-the-fly", between LO, HI, and MAG, for cable and line tracing with break locating, pinpointing a ferrous metal target, or identifying and pinpointing an energized 50/60 Hz power line.
In the LO and HI modes, the receiver's audio signal provides a sharp null when its tip is directly over the target. In the MAG mode (no transmitter required) the audio signal peaks when the receiver's tip is over the target. You can trace the 571 Hz LF signalconductively applied to any continuous metal conductor up to 4000 feet. The receiver's on-the-fly mode-changing feature lets you locate a complete break using the LO mode, and then continue on to trace beyond the break in the HI mode, or trace a metal pipe joined with nonconductivegaskets.The MAC-51Bx by simultaneously transmiting 82.5 kHz (HF) and 571 Hz (LF) signals. This feature lets you select and compare received audio signals from both frequencies along with magnetic information without having to return to the transmitter.Transmitter Inductive Mode (HF only) Induction is achieved by placing the transmitter over the target cable/pipe or by using the optional Inductive Signal Clamp.It's the easiest and quickest way to applying a trace signal that is strong enough for tracing most lines. The trace signal generates an alternating magnetic field around the cable which induces a signal into the receiver's cable sensor. A sharp null in the audio signal between the two peaks occurs when the receiver's tip is directly over the cable. Transmitter Conductive ModeIf an exposed section of a target gas or water pipe is accessible, conductive coupling is the most reliable method for applying the trace signal. This mode has to be used to apply both HF and LF frequencies so that you can use all three features on-the-fly. Providing a good electrical contact between the clip and the conductive portion of the target line by removing rust or paint before attaching the clip is very important.Magnetic Locating ModeOnly the MAC-51Bx receiver is required when operating in the magnetic mode. Just set the Mode switch to MAG, the Gain control to mid-range, and you're ready to locate underground ferrous pipes, water meters, water valves, and property markers - or anything that has a magnetic field including the 50/60Hz electro-magnetic field generated by energized power lines.SpecificationsReceiver
- Operating Voltage 9 V (2 alkaline or 2 lithium batteries)
- Battery Life 60hrs, alkaline (on & off usage @ 70ºF)
- 120 hrs, lithium (on & off usage @ 70ºF)
- Audio Output Approx. 40 Hz idling tone from speaker
- Freuency of pulsing tone (increases or
- decreases) with signal intensity
- Weight 2.64 lb. (1.20 kg.)
- Operating Temp. -13º F to 140º F
- Overall Length 42.3 in. (107.4 cm.)
- Waterproof
- Length 34.5 in. (87.6 cm.)
- Nominal Sensor Spacing 20 in. (50.8 cm.)
- Operating Voltage 12 V (8 alkaline C-Cell batteries)
- Battery Life 60 hours (on & off usage @ 70ºF)
- RF Output 82.5 kHz modulated at 382 Hz, pulsed at 4.4Hz
- 571 Hz Pulsed at 4.4 Hz
- Audio Indicator 2.58 kHz pulsed at 4.4 Hz
- Weight Approx. 5.5 lb. (2.5 kg.)
- Operating Temp -13ºF to 140ºF
- Overall Size 43.5 in. x 7 in. x 5 in.
$0.00
- Stock: In Stock
- Model: 125-7555