TSI Dustrak II 8530 Aerosol Monitor-RENTAL
TSI 8530 DustTrak II desktop aerosol monitors are battery-operated, datalogging, light-scattering laser photometers that give users real-time aerosol mass readings of dust, smoke, fumes, and mists insitu. The color touchscreen and graphical interface allows user on adjustments for sampling parameters, datalogging setting to be easily set or adjusted on site. An easy-to-read display shows real-time mass concentration, graphical data, and statistics, as well as instrument pump, laser, and flow status.
The TSI 8530 DustTrak II is compatible with the TSI 8535 aerosol particulate monitor field enclosure, which can be outfitted with visual and audible alarms, wireless antennae and modems for communication from the field to your control room. It's the ideal accessory for using your DustTrak II 8530 for monitoring perimeter dust monitoring applications, surveys in harsh environments, or to take measurements in areas exposed to changing weather conditions.Features
- Measures concentrations to PM10, PM2.5, PM1.0 or respirable size fractions
- STEL alarm setpoint
- Automatic zeroing (with optional zero module) minimizes the effect of zero drift
- Continuous real-time single-channel 90° light-scattering laser photometer
- Graphical color touchscreen interfaces
- Use with TSI 8535 Environmental Enclosure and Netronix Thiamis
- Compatible with TrakPro data analysis software
- Manual and programmable data logging functions
- Aerosol Concentration range 0.001 to 400 mg/m3
- Sensor Type: 90° light scattering
- Particle Size Range: 0.1 to 10 µm
- Aerosol Concentration Range: 8530 Desktop: 0.001 to 400 mg/m3
- Resolution: ±0.1% of reading or 0.001 mg/m3, whichever is greater.
- Zero Stability: ±0.002 mg/m3 per 24 hours at 10 sec time constant.
- Flow Rate: 3.0 L/min set at factory, 1.40 to 3.0 L/min, user adjustable.
- Flow Accuracy: ±5% of factory set point, internal flow controlled.
- Temperature Coefficient: +0.001 mg/m3 per °C
- Operational Temp: 32 to 120°F (0 to 50°C)
- Storage Temp: -4 to 140°F (-20 to 60°C)
- Operational Humidity: 0 to 95% RH, non-condensing.
- Time Constant: User adjustable, 1 to 60 seconds.
- Data Logging: 5 MB of on-board memory (>60,000 data points). 45 days at 1 minute logging interval.
- Log Interval: User adjustable, 1 second to 1 hour.
- Physical Size (H x W x D): Handheld: 4.9 x 4.8 x 12.5 in. (12.5 x 12.1 x 31.6 cm) Desktop: 5.3 x 8.5 x 8.8 in. (13.5 x 21.6 x 22.4 cm)
- Weight: 3.5 lb (1.6 kg), 4.5 lb (2.0 kg)–1 battery, 5.5 lb (2.5 kg)–2 batteries.
- Communications: USB (host and device) and Ethernet. Stored data accessible using flash memory drive.
- Power–AC: Switching AC power adapter with universal line cord included,115–240 VAC
- Analog Out: User selectable output,0 to 5 V or 4 to 20 mA. User selectable scaling range
- Alarm Out: Relay or audible buzzer Relay: Non-latching MOSFET switch, User selectable set point, –5% deadband, Connector 4-pin, Mini-DIN connectors
- Screen: 5.7 in. VGA color touchscreen
- Gravimetric Sampling: Removable 37 mm cartridge (user supplied)